Parts   

Fields marked with are required to add

New Parts


FlightPath has access to thousands of aviation parts in all categories at discounted pricess.

Viewing items 1 - 20
REMOTE AREA LIGHTING SYSTEM/IR
price: $1,209.05
part num: 9430IR
Pelican's new 9430IR (infrared) spotlight reaches down-range to provide situational awareness without compromising stealth. 24 infrared lamp modules generate light visible only to forces equipped with night vision equipment. Capable of operating 75 yards out, the 9430IR extends the tactical advantage of night vision technology.

Covert Checkpoint: Now soldiers can establish covert NV checkpoints to asses threats and provide advance warning to exposed personnel.

Perimeter Security: The 9430IR can be hand carried to remote locations. Equipped with night vision and digital communication, forces outside the perimeter can remain invisible and silent while using the 9430IR to report enemy movement.

RADIO CONTROL UNIT/ALUMINUM CASE
price: $823.90
part num: M2115RCU-A

Aluminum Enclosure (for indoor use)

The M2115RCU is a versatile, economical VHF-based radio control solution for hangar doors, gates, and other airfield applications where certification to FAA AC 150/5345-49C is not required.

  • Less Expensive, MORE FEATURES! Versatile unit provides unattended, all weather, air-to-ground radio control to operate hanger doors, control approach and runway end lights, taxi lights, or any other application where remote operation is desired from inside the aircraft.
  • Resume On Power Loss – Automatically energizes the same relays that were on when the power was lost significantly increasing flight crew safety especially in remote airfield locations.
  • Synthesized Tuning - No more Crystals! Customer programmable. Utilizing a standard DB-9 serial cable (included) use your PC to program the operating frequency and adjust sensitivity using custom PC software. Password required to change operating frequency for increased security.
  • Multiple Configuration Options – Can be configured for one, two or three relays. Has an 8 position DIP switch for setting configuration options. Operates like the older M15RCU unit. Same 3, 5 and 7 clicks to activate individual relays.
  • Indications. LED’s light up to display relay activation. A STATUS LED flashes to indicate normal operation. WINDOW LED indicates detection of a mic click.
  • Operates from any Available Power Source -Power from 9VDC, 12VDC, 24VDC, 30VDC, 115VAC, or from a solar panel with a battery back-up system for longer life and minimum maintenance.
  • 8 Different Time Out Values - No timeouts, 10 seconds (used for testing units), 5, 10, 15, 30, 45 & 60 minutes. Available in 8 and 12 hour timeouts intervals upon special request.
  • Test Button - Test controller circuits without radio inputs. Reset button resets relay after test.

GENERAL
  • Dimensions: 7.5" wide 4.5" high 2" deep excluding hardware
  • Case Type: Aluminum.
  • Power Required: 10 to 30 VDC (negative ground) 0.30 amp maximum or - 120 / 240 VAC +/-15% jumper selected at the factory (50 / 25 mA AC).
  • Recommended Protection: 1/8A / 250V for controller / radio. 5A for relay contacts. Choose between Fuse and Circuit breakers when ordering. Optional AC line and antenna lightning protection.
  • Temperature range: -20° F to +122° F (-30° C to +50° C)
  • Humidity: 95% non-condensing

RECEIVER
  • Antenna: SO-239 (UHF) 50 ohms with optional lightning protection (replaceable cartridge)
  • Frequency Range: 118.000 to 136.975 MHz
  • Channel Spacing: 25 KHz or 8.333 KHz
  • Sensitivity: 5 uv 30% mod. at 1 KHz gives at least 10 dB (S+N)/N into 600 ohms adjustable via potentiometer (<5 uV to >10,000 uV)
  • Selectivity: -6 dB at +/-9 KHz, -60 dB at +/-40 KHz
  • Adj Channel Selectivity: 65 dB at 25 kHz
  • Intermodulation: -65 dB type dB; typical at 25 kHz
  • Spurious Rejection: 80 dB at 25 kHz
  • Spurious Emission: Conducted: <-60 dBm
  • Radiated: -60 dBm < 1 GHz
  • Timebase Stability: +/-30 ppm, includes aging

CONFIGURATION AND USER INTERFACE
  • Test Switch: Pressing this activates the relays just as a received microphone click would.
  • Reset Switch: Resets all energized relays.
  • RS-232C Serial COM Port: Allows authorized changes of operating frequency via a Windows PC program (M2115RCUPC). Password Protected. Software Included.
  • Status LED: Blinks at a rate of once per second to indicate normal operation.
  • Window LED: Lights when the first valid click is detected. Remains on for the allowed window duration (3 to 5 seconds depending upon DIP switch settings)
  • Relay LED's: Visual indication of the adjacent relay state.
  • DIP Switches: Allows field configuration of relay timing and behavior.
  • Sw 1, 2 & 3 - "Timeout Period". (Variable from 3 seconds to 1 hour) (Optionally can be programmed for 8 hour and 12 hour max timeout)
  • Sw 4 - "Window Time" (3 sec or 5 sec)
  • Sw 5 - Relay Deactivate Disable. Relays will only de-energize at timeout period expiration.
  • Sw 6 - "Mutually Exclusive" relay operation. Only one relay is ever active at one time. When the 5 click relay energizes, the 3 click relay de-energizes. Same for the 7 click.
  • Sw 7 - "5 Click-Off" function. If only one relay is installed, this setting allows the customer to turn on the lights with 3 clicks, and turn them off with 5 clicks.
  • Sw 8 - "7 Click Off" function. Same as 5 Click off function except it turns all the energized relays off with 7 clicks.
  • Relays: 1, 2, or 3, form A, SPDT, standard unit 3 form A (SPDT), plug in for FAA unit.
  • Mechanical Life: 100,000 operations.
  • Switch Circuit Protection: Fuse or circuit breaker as specified by the user.

RADIO CONTROL UNIT/NEMA4 STEEL CASE
price: $933.90
part num: M2115RCU-S

Steel NEMA4 Enclosure

The M2115RCU is a versatile, economical VHF-based radio control solution for hangar doors, gates, and other airfield applications where certification to FAA AC 150/5345-49C is not required.

  • Less Expensive, MORE FEATURES! Versatile unit provides unattended, all weather, air-to-ground radio control to operate hanger doors, control approach and runway end lights, taxi lights, or any other application where remote operation is desired from inside the aircraft.
  • Resume On Power Loss – Automatically energizes the same relays that were on when the power was lost significantly increasing flight crew safety especially in remote airfield locations.
  • Synthesized Tuning - No more Crystals! Customer programmable. Utilizing a standard DB-9 serial cable (included) use your PC to program the operating frequency and adjust sensitivity using custom PC software. Password required to change operating frequency for increased security.
  • Multiple Configuration Options – Can be configured for one, two or three relays. Has an 8 position DIP switch for setting configuration options. Operates like the older M15RCU unit. Same 3, 5 and 7 clicks to activate individual relays.
  • Indications. LED’s light up to display relay activation. A STATUS LED flashes to indicate normal operation. WINDOW LED indicates detection of a mic click.
  • Operates from any Available Power Source -Power from 9VDC, 12VDC, 24VDC, 30VDC, 115VAC, or from a solar panel with a battery back-up system for longer life and minimum maintenance.
  • 8 Different Time Out Values - No timeouts, 10 seconds (used for testing units), 5, 10, 15, 30, 45 & 60 minutes. Available in 8 and 12 hour timeouts intervals upon special request.
  • Test Button - Test controller circuits without radio inputs. Reset button resets relay after test.

GENERAL
  • Dimensions: 7.5" wide 4.5" high 2" deep excluding hardware
  • Case Type: NEMA4 steel.
  • Power Required: 10 to 30 VDC (negative ground) 0.30 amp maximum or - 120 / 240 VAC +/-15% jumper selected at the factory (50 / 25 mA AC).
  • Recommended Protection: 1/8A / 250V for controller / radio. 5A for relay contacts. Choose between Fuse and Circuit breakers when ordering. Optional AC line and antenna lightning protection.
  • Temperature range: -20° F to +122° F (-30° C to +50° C)
  • Humidity: 95% non-condensing

RECEIVER
  • Antenna: SO-239 (UHF) 50 ohms with optional lightning protection (replaceable cartridge)
  • Frequency Range: 118.000 to 136.975 MHz
  • Channel Spacing: 25 KHz or 8.333 KHz
  • Sensitivity: 5 uv 30% mod. at 1 KHz gives at least 10 dB (S+N)/N into 600 ohms adjustable via potentiometer (<5 uV to >10,000 uV)
  • Selectivity: -6 dB at +/-9 KHz, -60 dB at +/-40 KHz
  • Adj Channel Selectivity: 65 dB at 25 kHz
  • Intermodulation: -65 dB type dB; typical at 25 kHz
  • Spurious Rejection: 80 dB at 25 kHz
  • Spurious Emission: Conducted: <-60 dBm
  • Radiated: -60 dBm < 1 GHz
  • Timebase Stability: +/-30 ppm, includes aging

CONFIGURATION AND USER INTERFACE
  • Test Switch: Pressing this activates the relays just as a received microphone click would.
  • Reset Switch: Resets all energized relays.
  • RS-232C Serial COM Port: Allows authorized changes of operating frequency via a Windows PC program (M2115RCUPC). Password Protected. Software Included.
  • Status LED: Blinks at a rate of once per second to indicate normal operation.
  • Window LED: Lights when the first valid click is detected. Remains on for the allowed window duration (3 to 5 seconds depending upon DIP switch settings)
  • Relay LED's: Visual indication of the adjacent relay state.
  • DIP Switches: Allows field configuration of relay timing and behavior.
  • Sw 1, 2 & 3 - "Timeout Period". (Variable from 3 seconds to 1 hour) (Optionally can be programmed for 8 hour and 12 hour max timeout)
  • Sw 4 - "Window Time" (3 sec or 5 sec)
  • Sw 5 - Relay Deactivate Disable. Relays will only de-energize at timeout period expiration.
  • Sw 6 - "Mutually Exclusive" relay operation. Only one relay is ever active at one time. When the 5 click relay energizes, the 3 click relay de-energizes. Same for the 7 click.
  • Sw 7 - "5 Click-Off" function. If only one relay is installed, this setting allows the customer to turn on the lights with 3 clicks, and turn them off with 5 clicks.
  • Sw 8 - "7 Click Off" function. Same as 5 Click off function except it turns all the energized relays off with 7 clicks.
  • Relays: 1, 2, or 3, form A, SPDT, standard unit 3 form A (SPDT), plug in for FAA unit.
  • Mechanical Life: 100,000 operations.
  • Switch Circuit Protection: Fuse or circuit breaker as specified by the user.

Pre-Owned Parts Inventory


FlightPath maintains an inventory of pre-owned avionics as a result of upgrades and 20+ years of accumulation.
If you don't see what you are looking for, try our RFQ form and we will get back to you with a quote.

Click to Enlarge
BENDIX/KING RDS-86 RADAR SYSTEM

View Item Details »

Promotions


As a result of our partnerships with various manufacturers we frequently receive special promotions that we pass on to our customers.

Promotion: Mid-Continent MD-302
Price: $10,295.00
Desc:
Promotion: ASPEN 1000 PRO
Price: $10,295.00
Desc: get your aspen installed out the door most aircraft for 10295.00

Part Request Form Fields marked with are required to add


  352-796-1663   ai: KBKV

Mid-Continent MD-302

View Promotion Details »

ASPEN 1000 PRO

View Promotion Details »

BENDIX/KING RDS-86 RADAR SYSTEM

View Item Details »