Nothing beats a Simpson 260-8 for monitoring fluctuating trends and rates. Portable yet with benchtop accuracy, the 260-8 is ideal for use anywhere -- workshop, lab or in the field. The 260-8P features an additional resettable overload protection circuit and audible continuity checking. Both versions come with batteries, manual and full-size test leads with threaded probe tips and screw-on alligator clips.
- Easy to operate -- two knobs control the selection of functions and ranges
- More than 20 measurement ranges for DC voltage and current, AC voltage and current, resistance
- Large, tri-colored dial with mirrored scale to prevent parallax error
- Reverse recessed safety jacks prevent operator and tool contact with electrical connections
- Rugged phenolic case with reinforced walls for maximum durability
- Self-shielding taut-band meter movement provides added shock resistance
DC Voltages:
Ranges: 250mV, 1V, 2.5V, 10V, 25V, 50V, 250V, 500V, 1000V
Accuracy: 2% full scale
Sensitivity: 20K per volt
AV Voltage:
Ranges: 2.5V, 10V, 25V, 50V, 250V, 500V, 1000V
Accuracy: 3% of full scale
Sensitivity: 5K per volt
DC Current:
Ranges: 50µA, 1mA, 10mA, 100mA, 500mA, 10A
Accuracy: 1.5% full scale 50µA; 2.0% of full scale, all others
Voltage drop(nominal): 250mV on 50µA/1mA; 255mV on 10mA/10A; 300mV on 100mA; 500mV on 500mA
AC Current:
Ranges: up to 250 amperes with AC amp-clamp adapter
Decibels:
5 ranges: -20 to +50dB
Reference: 0dB= 1mW into 600
Rated circuit-to-ground voltage:
1000V (AC or DC) max.
Fuse:
F1 1A, 250V, type 3AG, quick acting Littelfuse type 312001;F2 2A, 600V Littelfuse type BLS or 2A 600V, Bussman type BBS
Batteries:
1.5V AA, 9V (Neda No. 13F, 16004A)
Physical:
Dimensions 7" x 5.5" x 3.1" (18x14x8 cm)
Weight:
3 lbs (1.4kg)